WIDE TEMPERATURE RANGE (-30° to +75°C)
!
IDEAL FOR PORTABLE, MOBILE, OR STATIONARY INDUSTRIAL
APPLICATIONS
!
AVAILABLE IN TWO VERSIONS:
FRONT PANEL RESET OR REMOTE RESET
!
LOW COST/HIGH PERFORMANCE
!
OPERATES FROM SWITCH CONTACT OR OPEN
COLLECTOR INPUTS
!
PROVIDES YEARS OF SILENT OPERATION WITHOUT
MECHANICAL WEAR
!
SELF POWERED, ELIMINATES POWER WIRING
!
BUILT-IN STRAIN RELIEF
!
EASY SNAP-IN MOUNTING IN 1" X 2" (25 mm x 50 mm)
PANEL OPENING
MODEL CUB3L & CUB3LR -
General Purpose, Miniature Electronic Counters With
Lithium Battery - Economical Replacement For Electro-Mechanical Counters
DESCRIPTION
The CUB3Ls are miniature electronic counters. The CUB3L has front panel
reset, while the CUB3LR has remote reset. These units fill a wide variety of
applications.
The CUB3Ls feature a rugged reinforced nylon case that snap-fits into a
standard rectangular opening without screws or other hardware. Hook-up is
simply a matter of connecting two wires, and since the operating voltage is only
3 V and with currents in microamps, almost any kind of wire can be used. No
external power is required since the internal batteries provide years of
uninterruptible service. In addition to these advantages, the CUB3Ls offer the
inherent ruggedness, reliability, and permanence of completely integrated
circuitry, embedded in a single monolithic, silicon, micro-chip.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
SPECIFICATIONS
1.
DISPLAY
: 6-Digit, LCD, 0.2"
(5.1 mm)
High.
2.
POWER
: 3 V supplied by a lithium battery. Nominal battery life 10 years,
depending on usage.
3.
RESET
:
CUB3L
- Via front panel reset button only.
CUB3LR
-
(Remote Reset Only)
Switch Contact or Solid State Transistor
Switch
(See Connections)
. Contact burden 14 µA; Max. OFF-State
leakage current must be less than 2 µA. Counter resets with negative pulse
on a min. pulse width of 5 msec.
4.
COUNT INPUT
: Switch Contact or Solid-State Transistor Switch
(See
Connections)
. Contact burden 14 µA; Max. OFF-State leakage current must
be less than 2 µA. Counter increments on negative going edge of input.
5.
COUNT SPEED
: 100 counts/sec
(6000 counts/min)
. Min. input pulse width
5 msec, with 5 msec spacing between count pulses.
6.
ENVIRONMENTAL CONDITIONS
:
Operating Temperature
: -30° to +75°C
Storage Temperature
: -40° to +80°C
Operating and Storage Humidity
: 85% max. relative humidity (non-
condensing) from 0°C to 50°C.
Altitude
: Up to 2000 meters
7.
CERTIFICATIONS AND COMPLIANCES
:
SAFETY
IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment for
measurement, control, and laboratory use, Part 1.
ELECTROMAGNETIC COMPATIBILITY
Note:
Refer to the EMC Compliance Installation section of this bulletin for
additional information.
8.
CONSTRUCTION
: Installation Category I, Pollution Degree 2
9.
WEIGHT
: 3 oz. (85 g)
[less batteries]
WARNING:
Lithium battery may explode if incinerated. Signal input
voltage should not exceed 3.0 VDC to prevent damage to the battery.
CAUTION
: Read complete instructions prior to
installation and operation of the unit.
ORDERING INFORMATION
MODEL NO.
DESCRIPTION
PART NUMBERS
CUB3L
CUB3L (Front Panel Reset Only) w/Lith Bat.
CUB3L000
CUB3LR
CUB3LR (Remote Reset Only) w/Lith Bat.
CUB3LR00
Bulletin No. CUB3L/R-F
Drawing No. LP0127
Released 10/03
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion-controls.com
Enclosure class B
EN 55011
RF interference
Level 4; 30 A/m
EN 61000-4-8
Power frequency magnetic fields
150 KHz - 80 MHz
Level 3; 10 V/rms
EN 61000-4-6
RF conducted interference
Level 4; 2 Kv I/O
EN 61000-4-4
Fast transients (burst)
80 MHz - 1 GHz
Level 3; 10 V/m
EN 61000-4-3
Electromagnetic RF fields
Level 3; 8 Kv air
Emissions to EN 50081-2
Level 2; 4 Kv contact
EN 61000-4-2
Electrostatic discharge
Immunity to EN 50082-2
900 MHz, ±5 MHz
200 Hz, 50% duty cycle
ENV 50204
Level 3; 10 V/m
Simulation of cordless telephones