Wiring:

Dimensions (mm):

Start Up & Battery:

Entering Setup Mode:

The battery cover tabs are located on the back of the unit directly beside the terminal screws.  By pressing the two tabs
together at the same time, (toward one another), and pull the cover away from the unit itself will remove the battery.  The
battery is setting in the plastic cover.  After removing and replacing the battery, make sure that the new battery is placed
correctly in the cover so the unit will power up when the cover is placed back in the unit, (the plus and minus signs are
shown on the cover itself along with a picture of the battery orientation in the cover).

Note:  When the unit is first purchased, the battery is sent with tape on one side of the battery to keep the unit from powering
up. Remove the tape by following the above instructions on replacing the battery.  Also note that the setting is always reset to
FUNC-101 when the batteries are changed.  You must reset your function setting after replacing the battery.

1.  Connect terminal #2 to terminal #4 (Enable to Common)
2.  Connect terminal #3 to terminal #4 (Program to Common)
3.  Press and hold the reset button on the front of the unit for 10 seconds (LCD will display FUNC-101~FUNC-208
     depending on which mode the unit was in last)
4.  Press and release the reset button and the LCD will change to display the next function (example: FUNC-101 will now
     display FUNC-102), keep doing this until the display is showing desired function of the unit
5.  Wait for 10 seconds with the LCD display showing the desired function menu and the unit will store the function setting
6.  Disconnect terminal #2 from terminal #4
7.  Disconnect terminal #3 from terminal #4

 