![RDA FirePro V2 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/rda/firepro-v2/firepro-v2_manual_1424407032.webp)
Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
31
11 Menu
Settings can be set in the menu. On the PCB you will find 3 pushbuttons on the right side of the
display: "
˅
", "
˄
" and "
stop/OK"
(see image). These work in normal operation as up-stop-down
operation.
The menu can be opened by pressing the "
stop/OK
" button for about 3 seconds. The parameters
can then be scrolled with buttons "
˅
" and "
˄
". If the correct parameter is reached it can be opened
by pressing "
stop/OK
". Then it can be changed with the buttons "
˅
" and "
˄
". To go back to the
menu and confirm the change, press "
stop/OK
" briefly. To exit the menu go to parameter 0.0 and
press "
stop/OK
" briefly.
11.1
Parameter settings 0. :
Parameter
Description
Settings
0.0
Exit Menu
Exit the menu by pressing "Stop/OK"
0.1
Operating mode
.1 Hold to run Open, Hold to run close
.2 Automatically open, Hold to run close
.3 Automatic open and close with external
operation out of sight*
0.2
Type safety edge
.1 Automatically detect
.2 Choice opto sensors
.3 choice 1K2 DW/air pressure contact
.4 choice 8K2 electric contact
.5 No safety edge (only hold to run close
possible)
0.3
Operation safety edge
(parameter 0.1 op 3)
.1 Stop and send the door/roller shutter
completely open
.2 Stop when safety edge is activated and
continue only after re-pressing close
button