Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
22
9.16
Safety edge:
An safety edge can be connected to X12. This can be a resistance protection with a 1K2 resistor
(DW-contact) or with an 8K2 resistor. It is also possible to connect a security via Opto sensors
(see Fig. 14).
Figure 14 connecting safety edge
Caution, in the application of an safety edge, it is necessary to check and
be determined whether the door with electric actuator complies with the
Guidelines: EN 12445 and 12453. Locally applicable standards should also be
to be maintained!
9.17
Siren/Alarm:
On X13 two outputs are present as potential-free changeover contacts. One is
siren
. This switches
when the door/roller shutter is in motion and during the pre-warning before the door/roller shutter
closes depending on the menu's setting 4.1.
The other is
Alarm
. It switches at fire alarm, smoke detection and if it is chosen to close at low
battery voltage
(see Fig. 15).
Figure 15 outputs alarm and siren