Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
20
Fine adjustment Position:
By connecting the transmitter's black cable to the + 24V DC, the Adjust mode is turned
on. On the transmitter the green and yellow LED will flash alternately and on the receiver
the green LED must be lit and the red will blink. The faster the red LED flashes the better
the adjustment. If the green LED flashes, the adjustment is too bad for use!
Close mode by removing the black cable from the + 24V DC again and connecting it to
the 0 VDC (GND)
Reset to factory defaults:
Connect the Sync (white) wires for at least 15 seconds and up to 25 seconds with the +
24V DC.
Advice:
Remove after all the settings, the power from the light curtain and put it back on. The light
curtain, sets itself off to the correct luminosity
Error messages:
Channel:
No LED lights
Check power supply
Green lights > Yellow flashes every time 3x
Supply voltage receiver is plugged
in
Only yellow flashes 3x
White sync cables not (properly)
connected
Receiver:
No LED lights
Check power supply
Red LED flashes every 2x
Output cable incorrectly connected or
defective
Both:
If all Leds on both transmitter and receiver are blinking, the light curtain must be
replaced.