27
of day clock will reset to 0:00. The delay time is initially set at 10 days; but can be changed
by the user.
b)
PROD 1 display will show "dAtE". PROD 2 display will show "P dn". The DATA display will
show "10".
c)
To change the delay time enter a new number from 0 to 200 days.
d)
Momentarily depress
to advance to TIME.
e)
Momentarily depress
to advance to the FLOW RATE category.
FLOW RATE SCREENS
16)
VOLUME/MINUTE PRODUCT 1
a)
PROD 1 display will show "Fr". PROD 2 display will show "FLo1". The DATA display will
show the volume per minute of Product 1.
b)
Momentarily depress
to advance to VOLUME/MINUTE PRODUCT 2.
17)
VOLUME/MINUTE PRODUCT 2
a)
PROD 1 display will show "Fr". PROD 2 display will show "FLo2". The DATA display will
show the volume per minute of Product 2.
b)
Momentarily depress
to advance to VOLUME/MINUTE RATE FAULT PRODUCT 1.
18)
VOLUME/MINUTE RATE FAULT PRODUCT 1
a)
If the actual volume per minute falls below the set limit, the injection pump stops slowing
down, or the control valve stops closing, an alarm sounds and the PROD 1 display flashes
"-LL-".
The low limit value should be determined with all booms ON. This value is automatically
proportioned to the percentage of booms that are ON.
EXAMPLE:The entered low limit is 4. If half the total boom length is turned
OFF, the Console will automatically reduce the entered low limit to 2.
b)
PROD 1 display will show "Fr". PROD 2 display will show "LL 1". The DATA display will show
"0".
c)
Enter the set limit.
d)
Momentarily depress
to advance to VOLUME/MINUTE RATE FAULT PRODUCT 2.
19)
VOLUME/MINUTE RATE FAULT PRODUCT 2
a)
If the actual volume per minute falls below the set limit, the injection pump stops slowing
down, or the control valve stops closing, an alarm sounds and the PROD 2 display flashes
"-LL-".
Содержание SCS 700
Страница 1: ...Installation Service Manual SCS 700 ...
Страница 2: ...W A R N I N G Disconnect console before jump starting charging battery or welding on equipment ...
Страница 3: ......
Страница 4: ... ...
Страница 58: ...54 APPENDIX 9 INJECTION MODULE MOUNTING INSTRUCTIONS 1 TYPICALMODULEDIAGRAM ...
Страница 64: ...60 APPENDIX 14 SCS 710 6 BOOM CONSOLE WIRING DIAGRAM ...
Страница 69: ......
Страница 70: ......