25
NOTE:
The TRIGGER VALUE default value is "zero". This value must be changed to a
desired number ranging from 1-9999. The DATA LOGGER features will not work
if this number is not changed.
7)
DATA LOGGER TRIGGER UNITS
a)
PROD 1 display will show "SPr". PROD 2 display will show "Unit". DATA display will show
"Ft"["MEtr"].
b)
Depressing
momentarily changes the DATA display between "Ft"
[MEtr"] and "SEC". A value of "Ft"["MEtr"] means feet [meters], or a value of "SEC" means
seconds have been chosen as the unit of measurement for the TRIGGER VALUE
programmed previously.
c)
Momentarily depress
to advance to DATA LOGGER.
8)
DATA LOGGER ON/OFF
a)
The DATA LOGGER uses the communications strings listed in Appendix 16 to pass data
out through the serial port. The data is sent at a set time interval or a set distance traveled,
as determined by the values entered in the DATA LOGGER TRIGGER VALUE and DATA
LOGGER TRIGGER UNITS. Upon each trigger, the Actual Rate string, Data Strings 1, 2,
and 3, and the Time/date string are sent, in that order. When a Console calibration value is
changed, the Console will automatically send out the Cal 1, 2, and 3 strings. When a Console
switch is changed, the Data 1, 2, 3, Time/Date, and Cal 1, 2, 3 strings will be sent by the
Console. The Data, (with Time/Date string included) and Cal strings can also be requested
by the data logger using the request strings shown in Appendix 16.
b)
PROD 1 display will show "SPr". PROD 2 display will show "dLOG". DATA display will show
"oFF".
c)
Depressing
momentarily changes the DATA display between "oFF" and "on".
A value of "oFF" means DATA LOGGER is disabled; a value of "on" means DATA LOGGER
is enabled.
d)
Momentarily depress
to advance to CONSOLE DATA PRINTOUT.
e)
Momentarily depress
to advance to the GLOBAL POSITIONING SYSTEM category.
GLOBAL POSITIONING SYSTEM SCREENS
9)
GPS FILE REFERENCE
a)
PROD 1 display will show "GPS". PROD 2 display will show "FILE". DATA display will show
a "1".
b)
Enter the GPS file number.
c)
Momentarily depress
to advance to GPS SYSTEM OPTIONS.
Содержание SCS 700
Страница 1: ...Installation Service Manual SCS 700 ...
Страница 2: ...W A R N I N G Disconnect console before jump starting charging battery or welding on equipment ...
Страница 3: ......
Страница 4: ... ...
Страница 58: ...54 APPENDIX 9 INJECTION MODULE MOUNTING INSTRUCTIONS 1 TYPICALMODULEDIAGRAM ...
Страница 64: ...60 APPENDIX 14 SCS 710 6 BOOM CONSOLE WIRING DIAGRAM ...
Страница 69: ......
Страница 70: ......