52
APPENDIX 8
TANK INJECTION MODULE INSTALLATION
1.
PLUMBING THE INJECTION MODULE
1)
Plumb Pressure Relief Valve (PRV), Flow Meter, Control Valve, Carrier Check Valve, Product Check
Valves, and In-line Mixer just ahead of the Boom On/Off Valves as shown in Figure 4.
2)
Mount Injection Modules close to the Boom On/Off Valves to minimize amount of product in tubing.
3)
Plumb output lines of Injection Modules to Product Check Valves (See Figure 23). Use 3/8 inch [10
mm] tubing on low volume modules and 1/2 inch [13 mm] tubing on high volume modules. Product
Check Valves and tubing not furnished.
FIGURE 23