13
VERIFYING FLOW RATE LIMITS:
The gallons per minute (GPM) (liter per minute [lit/min]) flow rate of the sprayer must be within the
range of that specified for the Flow Meter included with the Console.
FLOW METER MODEL
FLOW RANGE
RFM 5
0.05-5 GPM [0.2-18.9 lit/min]
RFM 15
0.3-15 GPM [1.1-56.8 lit/min]
RFM 60P/60S
1-60 GPM [3.8-227 lit/min]
RFM 100
3-100 GPM [11.4-379 lit/min]
RFM 200/200 Poly
15-200 GPM [56.8-757 lit/min]
RFM 400
25-400 GPM [94.6-1514 lit/min]
2)
Determine the target application rate for PROD 2 CAL that you are spraying (Refer to the instructions
on the product container) using section DETERMINING INJECTION MODULE METER CAL.
FIGURE 8
Содержание SCS 700
Страница 1: ...Installation Service Manual SCS 700 ...
Страница 2: ...W A R N I N G Disconnect console before jump starting charging battery or welding on equipment ...
Страница 3: ......
Страница 4: ... ...
Страница 58: ...54 APPENDIX 9 INJECTION MODULE MOUNTING INSTRUCTIONS 1 TYPICALMODULEDIAGRAM ...
Страница 64: ...60 APPENDIX 14 SCS 710 6 BOOM CONSOLE WIRING DIAGRAM ...
Страница 69: ......
Страница 70: ......