62
APPENDIX 16
SCS 700/710 COMMUNICATION STRINGS
REMOTE COMPUTER TO SCS 700/710 CONSOLE
All request strings begin with $R, to indicate a Raven communication string.
Rate Change Request:
To set Prod Cal values for both products:
$R,RC,<prod_1_cal>,<prod_2_cal><CR><LF>
To set Prod Cal value for product 2 only:
$R,RC,,<prod_2_cal><CR><LF>
Calibration String Values Request:
$R,CR<CR><LF>
Data String Request:
$R,DR<CR><LF>
SCS 700/710 CONSOLE TO REMOTE COMPUTER
All console output strings begin with $R047F, the $R indicates a Raven communication string, the 047 is
the last three digits of the current SCS 700/710 programmed chip part number and F is the software revision
number.
Calibration Strings:
$R047F,C1,<switch_byte_1>,<switch_byte_2>,
<boom_1_cal>,<boom_2_cal>,<boom_3_cal>,<boom_4_cal>*,
<boom_5_cal>*,<boom_6_cal>*,<speed_cal> <CR><LF>
$R047F,C2,<meter_1_cal>,<meter_2_cal><CR><LF>
$R047F,C3,<valve_1_cal>,<valve_2_cal>,<prod_1_cal>,
<prod_2_cal><CR><LF>
Bit
Switch Byte 1 Switch Byte 2
0
boom 1
0
1
boom 2
0
2
boom 3
0
3
boom 4*
prod 1 auto
4
boom 5*
prod 1 manual
5
boom 6*
prod 2 auto
6
0
prod 2 manual
7
1
1
*
Booms 4, 5, and 6 are only in the SCS 710 Console strings.
NOTE:If prod auto and manual are both zero, the product is in Off.
For switch Byte Bits; 0 = off and 1 = on.
Data Strings:
$R047F,D1,<total_area>,<field_area><CR><LF>
$R047F,D2,<prod_1_volume>,<prod_ 2_volume><CR><LF>
$R047F,D3,<tank_1_volume>,<tank_2_volume>,<feet/meters><CR><LF>
Actual Rate:
$R047F,AR,<actual_rate_1>,<actual_rate_2><CR><LF>
Time/Date:
$R047F,TD,<hr:min>,<month/day/year>,<field_reference><CR><LF>
Содержание SCS 700
Страница 1: ...Installation Service Manual SCS 700 ...
Страница 2: ...W A R N I N G Disconnect console before jump starting charging battery or welding on equipment ...
Страница 3: ......
Страница 4: ... ...
Страница 58: ...54 APPENDIX 9 INJECTION MODULE MOUNTING INSTRUCTIONS 1 TYPICALMODULEDIAGRAM ...
Страница 64: ...60 APPENDIX 14 SCS 710 6 BOOM CONSOLE WIRING DIAGRAM ...
Страница 69: ......
Страница 70: ......