30
d)
Momentarily depress
to advance to AUDIBLE ALARM ON/OFF.
e)
Momentarily depress
to advance to the MISCELLANEOUS category.
MISCELLANEOUS SCREENS
25)
DISPLAY SMOOTHING ON/OFF
b)
Momentarily depressing
changes the DATA display between "on" and "oFF". A value
of "on" means smoothing is enabled; a value of "oFF" means smoothing is disabled. The
percent smoothing is determined by the third digit of VALVE CAL value as shown:
Brake Point Digit
(3rd digit) of VALVE CAL 2 1 2 3
0 = 1% + Deadband
5 = 25% + Deadband
1 = 3% + Deadband
6 = 30% + Deadband
2 = 7% + Deadband
7 = 35% + Deadband
3 = 10% + Deadband
8 = 40% + Deadband
4 = 20% + Deadband
9 = 45% + Deadband
Actual rate is displayed if unit does not reach deadband within 10 seconds. "oFF" means
RATE displays the actual rate at all times.
c)
Momentarily depress
to advance to AGITATOR PRODUCT 1.
26)
AGITATOR PRODUCT 1
a)
PROD 1 display will show "MiSC". PROD 2 display will show "AG 1". DATA display will show
"oFF".
b)
Momentarily depressing
changes the DATA display between "on"
(agitator 1 enabled) and "oFF" (agitator 1 disabled).
c)
Momentarily depress
to advance to AGITATOR PRODUCT 2.
27)
AGITATOR PRODUCT 2
a)
PROD 1 display will show "MiSC". PROD 2 display will show "AG 2". DATA display will show
"oFF".
b)
Momentarily depressing
changes the DATA display between "on"
(agitator 2 enabled) and "oFF" (agitator 2 disabled).
c)
Momentarily depress
to advance to AREA/HOUR.
Содержание SCS 700
Страница 1: ...Installation Service Manual SCS 700 ...
Страница 2: ...W A R N I N G Disconnect console before jump starting charging battery or welding on equipment ...
Страница 3: ......
Страница 4: ... ...
Страница 58: ...54 APPENDIX 9 INJECTION MODULE MOUNTING INSTRUCTIONS 1 TYPICALMODULEDIAGRAM ...
Страница 64: ...60 APPENDIX 14 SCS 710 6 BOOM CONSOLE WIRING DIAGRAM ...
Страница 69: ......
Страница 70: ......