22
DISPLAY SCREEN
PROD 1
PROD 2
DATA
FEATURE and DESCRIPTION
DATE SCREENS
dAtE
tiME
0:00
TIME
Time of day.
dAtE
onth
0
MONTH
Current month of year.
dAtE
daY
0
DATE
Current date of month.
dAtE
YEAr
0
YEAR
Current year.
dAtE
P dn
10
POWER DOWN
Puts Console into low power mode.
FLOW RATE SCREENS
Fr
FLo1
0
VOLUME/MINUTE PRODUCT 1
Displays volume per minute of Product 1.
Fr
FLo2
0
VOLUME/MINUTE PRODUCT 2
Displays volume per minute of Product 2.
Fr
LL 1
0
VOLUME/MINUTE RATE FAULT PRODUCT 1
Turns alarm ON if Product 1 actual volume per minute
falls below this limit.
Fr
LL 2
0
VOLUME/MINUTE RATE FAULT PRODUCT 2
Turns alarm ON if Product 2 actual volume per
minute falls below this limit.
ALARM SCREENS
ALr
ALrM
on
AUDIBLE ALARMS ON/OFF
Turns audible alarms ON or OFF for the following:
1)
Volume/Area Rate Alarm
2)
Volume/Minute Rate Fault
3)
Low Tank Fault
4)
Vacuum Alarm
5)
Flow Alarm
6)
Flow Error Alarm
ALr
vL 1
on
VACUUM AND FLOW FAULT PRODUCT 1
Turns alarms ON or OFF for a vacuum or flow fault in
Product 1 injection pump.
ALr
vL 2
on
VACUUM AND FLOW FAULT PRODUCT 2
Turns alarms ON or OFF for a vacuum or flow fault in
Product 2 injection pump.
Содержание SCS 700
Страница 1: ...Installation Service Manual SCS 700 ...
Страница 2: ...W A R N I N G Disconnect console before jump starting charging battery or welding on equipment ...
Страница 3: ......
Страница 4: ... ...
Страница 58: ...54 APPENDIX 9 INJECTION MODULE MOUNTING INSTRUCTIONS 1 TYPICALMODULEDIAGRAM ...
Страница 64: ...60 APPENDIX 14 SCS 710 6 BOOM CONSOLE WIRING DIAGRAM ...
Страница 69: ......
Страница 70: ......