95
SCC
Edition 10-2008a
Service Messages SCC
Service 20
Thermocouple B1 cabinet
Unit without function
- Appears on time
- Thermocouple broken or out of range
- Buzzer sounds 30 seconds
- Unit without function
- Appears for 30 sec. after switch ON
- Display can be cancelled by touch
- Micro switch ClimaPlus without function during start routine
- Manual cooking without humidity control possible
Not
activated
- Since SW 01-07-09 only!
- Display at once when: Temp. B5 raises above 100°C (212°F) for
60sec. without energy demand
- Intermittent buzzer 30 sec
- Unit without function
- Since SW 01-07-09 only!
- Display at once when: Temp. B1 raises starting from 150°C
(300°F) to above 200°C (300°F) without energy demand
- Intermittent buzzer 30 sec
- Unit without function
- Display can be cancelled
- Remove container from cabinet
- CleanJet pump does not deliver
- Fan motor does not reduce speed
- Water must hit left rack at rail 3-4
- Check water tap, pump, quenching solenoid (re ll function),
quenching nozzle or or CleanJet pipe for blockage
- Appears on time when CleanJet is selected
- Cooking not possible - drain closed
- Micro switch drain valve in permanent closed position
- Replace drain valve assembly
- Appears for 30 sec. after switch ON
- Display can be cancelled switch
- drain valve in permanent open position, CleanJet not possible
- Check micro switch drain valve
- Start rinse (abort) program
Service 21
Micro switch ClimaPlus
Maintenance needed
Service 22
Service 23
SSR Steam short circuit
Unit without function
Switch unit OFF
Service 24
SSR Hot air short circuit
Unit without function
Switch unit OFF
Service 25
No water detection by fan motor
CleanJet no function
Rinse
manually
Service 26
Drain valve closed
Unit without function
Service 27
Drain valve doesn‘t close
CleanJet operation not possible
Maintenance needed
Содержание SCC Series
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...