9
CM
Edition 10-2008
Water level control Steam Generator
V
AC
S2
M4
Y1
Y2
B2
S2
B5
F3
Center S2 ==> Ground:
2 - 6V AC:
water level too low
steam heating must switch OFF
solenoid
valve
lling
Y1
ON
Center S2 ==> Ground:
0V AC:
water level reached
steam heating can switch ON
solenoid valve lling Y1 switched OFF
Every 2 minutes steam elements will switch off for
water level control
PCB
X12
1 2 3 4
Содержание SCC Series
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...