15
CM
Edition 10-2008
Fan motor 40.00.274
Jumper 40.01.581 is used on oor model 201 and 202 for top position motor only!
Jumper is not used on models 61 - 102 with one motor only!
If jumper is not set correctly E12 will be displayed!
LED code fan motor SCC and CM from 04/2004
Reason
Remedy
1x
Motor doesn’t start, no changing
signal from hallsensor
Check for motor blockage or change motor.
2x
Voltage too low on motor pcb
Check supply voltage or
change motor.
3x
Voltage too high on motor pcb
Check supply voltage or
change motor.
4x
rpm measurement defective
Change motor.
5x
Motor pcb temperature >105°C
Check cooling system (cooling fan, air
intake lter), otherwise change motor
6x
Supply voltage <80V
Check power supply
(F1-F2)
7x
Motor pcb defective
Change motor.
8x
Motor pcb defective
Change motor.
Units 3AC400-480V (without neutral) are equipped with motor 40.00.276 (3-phase supply)
This motor is equipped with a 4 pole plug for the supply voltage.
LED
Jumper
Содержание SCC Series
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...