Function test SCC
Flue gas analysis Gas blower Hot air top:
Press START to operate hot air gas burner bottom;
- CO
2
adjustment with CO
2
screw at Max rpm
-
CO
2
cross checking at Min rpm
-
Flame current should be always above 4,0 A,
ideally
5,0-5,75
A
Flue gas analysis Gas blower Hot air bottom:
Press START to operate hot air gas burner bottom;
- CO
2
adjustment with CO
2
screw at Max rpm
-
CO
2
cross checking at Min rpm
-
Flame current should be always above 4,0 A,
ideally
5,0-5,75
A
Activation buzzer
Activation interior light
- Testing of all display lights by pushing and holding Start key.
The different lights will be activated in sequence.
19 - Function Test
Display
light
18 - Function Test
Interior
light
17 - Function Test
Buzzer T2
0 - 1
Gas Hot Air Blower Bot.
Max - Start - Min
CO2 FC
rpm
xxx% 5,25A xxx
16 - Function Test
Gas Hot Air Blower Top
Max - Start - Min
CO2
FC
rpm
xxx%
5,25A xxx
Start
Start
Start
Start
Start
Содержание SCC Series
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...