169
Trouble shooting SCC
Edition 10-2008a
Check polarity (Gas units)
For ame monitoring mains must be connected with correct polarity
Unit shows
Check polarity
Check power connection for cor-
rect polarity, colour code:
Live = brown or black
Neutral = blue
„RESET“ indication (Gas units)
Reason:
Flame monitoring does not work after ignition
Indication „RESET“
NO
Does the connected gas
type comply with the gas type
on the name plate?
Open gas supply
Switch on ventilation system
Convert unit to connected gas
type.
Follow instruction of training
manual
Attention: Carry out ue gas
analysis
Reset was carried out several
times?
Service 33 comes up if reset was
carried out 4 times.
Service 33 can be deleted by
switching unit off and on again
(function implemented as of soft-
ware version 01_07_08)
YES
Gas supply open
External Ventilation system
on?
- Cross section of the gas
supply pipe is too small
- Flow gas pressure is too
Reset only in case all
gas appliances of the kitchen
are switched on ?
Install suf cient supply pipe,
and/or increase gas pressure
Check ignition-electrode, -cable,
-box and gas valve
YES
NO
YES
NO
Содержание SCC Series
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...