19
CM
Edition 10-2008
F
CM - Sequence of events
Mode: Finishing;
Temp. range 30-300°C (86-572°F)
Function Step
Responsible sensor
1. Select Finishing mode
Recommended
temperature
30-300°C (86-572°F)
2. Select time or core temperature
3. Close cabinet door
Reed switch S3
4. Check water level inside steam generator
Level electrode S2 inside Steam Generator
5. Time based preheating of steam generator,
Thermocouple B5 inside Steam Generator
if B5 is below 85°C (185°F);
6. Timer starts after successful preheating
Logic on PCB
(blinking dot in Display)
7a. Electric units: alternating
12 sec. Hot Air
Cabinet sensor B1
6 sec. Steam
Quenching sensor B2
7b Gas units: alternating
30 sec. Hot Air
Cabinet sensor B1
15 sec. Steam
Quenching sensor B2
8. Quenching (set to 70°C/158°F)
Quenching sensor B2
Note: Reduction of fan motor speed
In case the actual
temperature
in the range of
30-99°C
(86 - 210°F) is 2°C / 4°F higher
than the set temperature for longer than 2 minutes, the fan speed will be reduced automati-
cally.
B1
B3
F4
M4
Y1
Y2
B2
M1
S2
B5
F3
S3
Содержание SCC Series
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...