48
SCC
Edition 10-2008a
General information to software version SCC 04-01-01
Software SCC 04-01-01 can also be used for units with index „E“ (from 04-2004).
With this software you have the following options:
Using the button “Cleanjet request” you can select the “Intelligent Cleanjet request”.
In this case the cleanjet request will be based on used cooking programs, tempratures
and cooking duration.
Selecting Cleanjet you will see the below symbol in window 4 of your display:
The second setting to choose is Cleanjet request based on cooking time only (as known from older
software versions).
In order to deselect the Cleanjet request (turn symbol from red to blue again) select time functions
and setb time to “0”..
In Service Mode Basic Settings position 26 you select „Softwater“ ON to indicate only the half
amount of detergent tabs when cleanjet is choosen. The individual tab setting (as available since
software SCC 03-01-01) is no more existing.
Software SCC 04-01-01 in units with index „G“ (from 10-2008)
Basic Settings 26 „Softwater“
In Service Mode Basic Settings position 26 you select „Softwater“ ON to indicate only the half
amount of detergent tabs when cleanjet is choosen.
Basic Settings 28 „Selftest“:
After installation the unit will ask the user to start a Selftest. Water MUST be connected!
After the Clima Control valve and the drain valve have initialised the steam generator will ll,
SC pump will start shortly and Y1 will re ll again.
In case the temperatures of B1, B2 and B4 are below 40°C now “Start” will be displayed.
After pressing “Start” the unit will adapt to the present installation conditions (duration appr. 15 min).
Should the unit be installed later at a different location, this “Selftest” can be re-initialised by setting
“Selftest” to ON in basic settings position 28.
Basic Settings 29 „Warranty“:
After rst switch on the unit will prompt the customer to register and validate his second year war-
ranty online under www.rational-ag.com/warranty.
This prompting will discontinue after 4 days.
After registration a warranty certi cate will be issued:
In case the unit was installed in a show room or exhibition, this prompting can be re-initialised by set-
ting “Warranty” to ON in basic settings position 29.
Basic Settings 30 „Steam corrosion control“
The unit automatically recognises if the customer used it predominantely in steam mode. In case this
usage is more than 90% during the last 20 hours of operation the unit will prompt a Cleanjet request
daily regardless of the total duration of cooking time
Basic Settings 31 „Care Control Reset“
By setting the switch to “ON” all Care Control bars will be set to blue.
Содержание SCC Series
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...