- 85 -
V08 en, SCC
CM_P - Function test - F
Motor bottom MIN rpm
floor models only
BUS
Set rpm
Act. rpm
clockwise
201 / 202 only
Motor bottom MIN rpm
floor models only
BUS
Set rpm
Act. rpm
anti clockwise
201 / 202 only
Solenoid valve
quenching
X19:(2-4)
actual temp.
B2 quenching
Y2
1 / 0
Solenoid valve
filling
X19:(1-3)
Level electrode
S2, 1 / 0
Y1
1 / 0
SC Pump
X18:(1-2) M4
X12:(1-4) S2
Level electrode
S2, 1 / 0
M4
1 / 0
Buzzer
X8:(1-2)
1 / 0
All Displays / LED
Relays Ultravent /
extraction hood
X 23: (1-2-3)
1 / 0
Y5 Clima valve
1 / 0
Gas blower Steam MIN
rpm
BUS
actual rpm
Set CO2
Check CO2
value
Gas blower Steam Start
rpm
BUS
actual rpm
Gas blower Steam MAX
rpm
BUS
actual rpm
Set CO2
Adjust CO2
value with
CO2 screw
Gas blower Hot air top
MIN rpm
table units / floor units
top
BUS
actual rpm
Set CO2
Check CO2
value
Gas blower Hot air top
Start rpm
table units / floor units
top
BUS
actual rpm
Gas blower Hot air top
MAX rpm
table units / floor units
top
BUS
actual rpm
Set CO2
Adjust CO2
value with
CO2 screw
Gas blower Hot air bottom
MIN rpm
floor units bottom
BUS
actual rpm
Set CO2
Check CO2
value
Gas blower Hot air bottom
Start rpm
floor units bottom
BUS
actual rpm
Gas blower Hot air bot-
tom MAX rpm
floor units bottom
BUS
actual rpm
Set CO2
Adjust CO2
value with
CO2 screw
Drain valve 90°
micro switch
1 / 0
Drain valve 270°
micro switch
1 / 0
Cleanjet pump M6
1 / 0
Содержание CombiMaster Plus CM
Страница 1: ... V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08 ...
Страница 3: ... 3 V08 en SCC ...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS ...
Страница 25: ... 25 V08 en SCC ...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active ...
Страница 74: ...V08 en SCC 74 ...