- 69 -
V08 en, SCC
Error message Service 55 - 120
Display
Definition
Reason and remedy
Service 52
Error LED pcb con
-
trol / connection
Check cable at LED PCB A7 to A8
Service 55
(only error
history)
internal error of fan
motor top
No Service 34.x error!
top motor doesn‘t turn, hot air heating is blocked
software tries to reset error every 10 seconds
see list below
Service 56 (only
error history)
internal error of fan
motor bottom
No Service 34.x error!
bottom motor doesn‘t turn, hot air heating is blocked
software tries to reset error every 10 seconds
see list below
Service 60
No gas blower rpm
information available
PCB does not send rpm information for gas blower
Switch unit off and on again,
run SD Repair program
Service 63
Unit had done a selftest
without water;
Now water was detected by the level electrode.
Cool down unit, make sure B1, B2 and B4 is below 40°C, (140°F)
In basic settings - Self test set Self test to ON and switch unit off and on again.
Run Self test
Service 110
SC Pumpe not working
while care solution is
inside steam generator.
Malfunction of SC pump during the time when Care solution was inside the steam
generator,
Follow error tree Service 10
Reset error by successful completing ABORT program;
Service 120
Level electrode wit-
hout signal while care
solution is inside steam
generator.
Water the level electrode does not recognise water during the time when Care
solution was inside the steam generator,
Solenoid valve Y1 or level electrode defective;
Reset error by successful completing ABORT program;
The error messages can be seen under Diagnostic, Service history.
Blink code motor SCC_CMP
Blink code Motor
Reason
Remedy
No Service 34.x error! - Motor doesn‘t turn, hot air heating is blocked
1x
Starting error
check if fan wheel is not blocked and can turn freely, change
motor
2x, 4x, 7x, 10x,
Motor defective
change motor
3x,
internal error
SCC_WE: flash software to 05.00.11.4 or higher
5x, 11x
Motor temperature too high
Check fan wheel dimension, change motor
6x,
voltage error
check voltage supply, change motor
8x
only with 3AC motor 40.03.514
phase is missing
9x
communication error
check bus cable, apply contact grease (9003.0219) to bus cable
plug
Содержание CombiMaster Plus CM
Страница 1: ... V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08 ...
Страница 3: ... 3 V08 en SCC ...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS ...
Страница 25: ... 25 V08 en SCC ...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active ...
Страница 74: ...V08 en SCC 74 ...