- 47 -
V08 en, SCC
Format of HACCP data
HACCP-Data are shown in the following format:
*** H A C C P ***
;
; Ch-nr. >>210<< = batch number
(number of stored cooking processes)
; Type >>SCC_101<<
= unit type
; Serial nr.>>G11SH151224923212<< = Serial number of the unit
; Version >>SCC - (s/o/C)<< = Software version of the unit
(„C“ indicates, delay of CleanJet request is activated
Only chain units:
„s“ or „o“ shows unit ran on
(s) Supervisor- or (o) Operator mode.)
; Time >>2011.09.20 12:27:26<< = Starting date and time of the cooking process
; Progr. >>Roast<< = Program name
(if „>><<“ appears, manual mode was used)
; #1 : Gartemp. / cabinet temp.
; #2 : Kerntemp. Soll / core temp. target
; #3 : Kerntemp / core temp.
; #4 : Zeit (Std:Min:Sek) / time (h:min:sec)
; #5 : Temp. Einheit / temp. unit
; #6 : Energie Opt. / energy opt.
; #7 : Energie 1/2 / energy 1/2
; #1 #2
#3
#4
#5
#6
#7
Mode HOT AIR
27 -
26
000:00:00
C
0
-
; Door closed
000:00:00
27 -
26
000:00:01
C
0
-
; Mode STEAM
27 -
26
000:00:03
C
0
-
30 -
28
000:01:00
C
0
-
; Mode COMBI
30 -
28
000:01:04
C
0
-
106 -
60
000:02:00
C
0
-
126 -
103
000:03:00
C
0
-
170 -
140
000:04:00
C
0
-
160 -
150
000:05:00
C
0
-
159 -
155
000:06:00
C
0
-
170 -
162
000:07:00
C
0
-
162 -
162
000:08:00
C
0
-
165 -
161
000:09:00
C
0
-
161 -
161
000:10:00
C
0
-
; end
000:11:00
; end = End of cooking process
B) Additional indications:
Progr. >>SCC - Universal Roast<< =
Indication of selected SCC process
Progr. >>SCC - ~ pork<< =
Copied SCC process with new name
Door opened or Door closed = during cooking process
Start (power failed)
= Power failure longer than 15 minutes
end (HOME) = Process terminated with Home key
end (RETURN) = Process terminated with arrow back key
end (ERROR) = Process terminated because of error
start ELC
= ELC Process started
restart (POWER)
= restart after switching off or power fail
end
= Process finished
Содержание CombiMaster Plus CM
Страница 1: ... V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08 ...
Страница 3: ... 3 V08 en SCC ...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS ...
Страница 25: ... 25 V08 en SCC ...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active ...
Страница 74: ...V08 en SCC 74 ...