V08 en, SCC
- 24 -
CM_P Index I/ CM Index I
CM 61 - 101
The basic model CM with index I has the identical construction as CM_P index H. It is only available in size 61 and
101 (without Cleanjet) and only with right hinged door.
CM_P with CleanJet
PCB
All CM_P with index I have a new PCB 42.00.272
Hand shower:
All CM and CM_P with index I get a new hand shower roll guide
(56.00.061).
Door:
All CM_P units 60 - 202 are equipped with a new door with 2 glass panes and halogen light
inside the cabinet. (without LED light, only halogen light in the cabinet
Only the CM_P XS (60) has a LED light in the door like SCC_XS (without level indication, without halogen light).
CM_P XS:
In order to connect the unit to the drinking water supply, water protection according EN 1717 must be ensured by
installing a double check valve, a type CA system divider or similar in the fresh water line.
Additional function
CALC - Descaling steam generator
Caution!
Descaler shall ONLY be filled through the steam inlet port inside the interior cabinet!
Protective clothing must be worn.
Interior cabinet temperature must be below 40°C (104°F);
Steam generator will be emptied, refilled and emptied again;
„CALC“ „FILL“: prompt to fill descaler into the steam generator;
30 second waiting time (to rinse cabinet with water);
“door”: prompt to close cabinet door;
45 minutes reaction time for the chemical,
“CALC”: Steam generator will be rinsed twice and refilled again;
Steam mode for 15 minutes
“END” and buzzer for 20 seconds
Display:
Call service partner to descale steam generator
Содержание CombiMaster Plus CM
Страница 1: ... V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08 ...
Страница 3: ... 3 V08 en SCC ...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS ...
Страница 25: ... 25 V08 en SCC ...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active ...
Страница 74: ...V08 en SCC 74 ...