Error message Service 30 - 44
Display
Definition
Reason - Remedy
Service 30
(only error
history)
humidity control not
working properly
humidity control via P1 not working.
no humidity control above boiling point
Steam is controlled via B2 quenching sensor (bypass control)
Check P1 and B4 in diagnostic mode
Service 31.xx
Core probe faulty
Most cooking processes do not work with defective core probe!
31.1: shaft probe 31.2- 5th probe (close to shaft)
31.4: 4th probe 31.8: 3rd probe
31.16: 2nd probe 31.32: 1st probe in tip
- Combination of faults possible i.e.: 10 -->2+8)
Change core probe
Service
32.0-1-2
no flame detection after
ignition
0 - top, 1 - bottom, 2 - both
Only change ignition box when gas error 33, 36, 39 or 42 happened more
often than 5x
refer to gas error list
Service
33.0-1-2
no flame detection after
ignition
- Appears after 3x Reset command without positive result
- 0 - top, 1 - bottom, 2 - both
- Check ignition wire, ignition box, gas valve and gas supply.
refer to gas error list
Service 34.xx
Bus signal does not res-
pond to PCB
Bus cable, bus component or power supply to bus component faulty
34.1: Motor top 34.2: Motor bottom
34.4: Ignition module top 34.8: Ignition module bottom
Combination of faults possible i.e.: 10 -->2+8
Check power supply and LED ON
Check jumper on floor unit bottom motor and ignition box
Change bus connection sequence
if error message changes bus cable is defective
if error message remains the same, component is defective
Service 35
Ultravent does not process
bus signal
Ultravent PCB not processing bus signal
Check power supply to UV
Blinking LED means power supply and PCB ok.
Service 36
Differential pressure sensor
P1 defective
No offset signal (0.5V)
P1 must be installed horizontally!
Check 12Vdc power supply to P1, plug,
Change P1
Service 37
Differential pressure sensor
P1 out of range
Differential pressure sensor P1 not in expected range,
check connection / blocking of P1 hoses.
Service 40
Care pump doesn`t pump
enough volume into steam
generator
Care pump blocked or defective or hose from care pump to steam generator
(partially) blocked
Check care pump in function test - Caution: Y4 is active at the same time, care
container might overflow when activating too long.
Check if the hose from the care pump outlet is not kinked;
Reset error by successful completing rinse program;
Service 41
no water flow when Y3 is
active during CJ+C
Solenoid valve Y3 defective or moistening nozzle and connecting pipe is blo-
cked; CDS does not send any pulses;
Check Y3 in function test, Remove nozzle (15mm), decale nozzle and clean pipe
from scale deposit. Rinse pipe in function test Y3 before mounting nozzle back.
Reset error by successful completing rinse program;
Service 42
no water flow when Y4 is
active during CJ+C
Solenoid Y4 Care defective or hose to care container blocked or kinked; CDS
does not send any pulses;
Check Y4 in function test,
Reset error by successful completing rinse program;
Service 44
No steam heating during
CJ+C
No temperature raise above 60°C (140°F) recognised by B1
Check SSR
Reset error by successfully completing rinse program;
Содержание CombiMaster Plus CM
Страница 1: ... V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08 ...
Страница 3: ... 3 V08 en SCC ...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS ...
Страница 25: ... 25 V08 en SCC ...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active ...
Страница 74: ...V08 en SCC 74 ...