- 67 -
V08 en, SCC
Error message Service
Display
Definition
Reason - Remedy
Service 10
water is not pumped off
during SC-Automatic
SC pump defective or blocked
Drain hose of SC pump blocked
Check SC pump and hose
Service 11
CDS sensor sends too many
pulses during refilling steam
generator
CDS sensor not set to 1000 pulses / liter
Air brake valve above steam generator not closing during filling
Check level electrode and water path to steam generator for leakage
Service 12
CDS sensor
without signal
CDS sensor defective, but level electrode senses water
Check water pressure, replace CDS sensor
Service 13
Steam generator is not
refilled during steam mode
Steam generator is not refilled during steam mode => foced filling
check 0-1 signal of level electrode to PCB
Service 14
Level electrode doesn`t
recognise water;
CDS sensor measured enough pulses but level electrode does not sense water
Check water conductivity possibly too low, osmosis water treatment
Service 17
Conflict with external me
-
mory SD card
essential unit data are missing (energy, size, etc)
Run recovery software
Service 19.1
Conflict with external me
-
mory SD card
Data can not be written successfully onto SD card
Change SD card
Service 20 -x- Thermocouple
defective
thermocouple defective.
20.1=cabinet B1
20.2=control B2
20.4= humidity B4
20.8= steam generator B5
(e.g. 20.12 = B4 + B5)
Service 21 (only
error history)
Voltage and current moni-
toring on PCB
1- 18V from T1, 2 - 12V on PCB, 4 - high current MMI, 8 - high current Drain
valve M7, 9 - high current humidity valve Y5
Service 25
No water flow detected
during CleanJet
during CCare the fan motor does not an increase in power demand
when water hits the fan wheel. -
check water pressure, water supply, moistening valve and nozzle and CDS
sensor.
GN racks or trolley properly inserted.
Service 26
Drain valve does not find
the open position
Micro switch drain valve not working properly
Initialise drain valve in basic settings, water, Cleanjet/Care, drain valve
time ration should be 1/4 : 3/4, e.g 9:27 sec or 6:18 sec.
test drain valve in function test
if drain valve not working change drain valve assembly
Service 27
Drain valve does not find
the closed position
Micro switch drain valve not working properly
Initialise drain valve in basic settings, water, Cleanjet/Care, drain valve
time ration should be 1/4 : 3/4, e.g 9:27 sec or 6:18 sec.
test drain valve in function test
if drain valve not working change drain valve assembly
Service 28
Thermocouple B5 above
180°C
Indication goes off when temperature below 110°C (230°F)
check if steam element is covered in scale.
Service 29
PCB temperature above
85°C (185°F)
Check air filter, cooling fan and control panel gasket
Check for external heat sources
1 - 29
Содержание CombiMaster Plus CM
Страница 1: ... V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08 ...
Страница 3: ... 3 V08 en SCC ...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS ...
Страница 25: ... 25 V08 en SCC ...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active ...
Страница 74: ...V08 en SCC 74 ...