V08 en, SCC
- 46 -
Format of unit service data
Startup report version (2)....: 20141029144122 Software update to version 06.00.05
Startup report version (3)....: 20160203083546 Software update to version 06.00.06
Startup report version (4)....: 20160322121432 Software update to version 06.00.08
Date and Time................ .: 20120515092835
Startup Date and Time.........: undef Unit type.....................: SCC_62
Energy type........... ........: G
Unit Serial number......... ...: G62SH12022208034 Software version..............: SCC-06-00-08
Script version................:
SW-update Date and Time.......: undef CPU-Board Revision............: 0506
CPU-Board Serial number.......: 25233859
CPU-Board Manufacturing date..: 2011-05-19 17:57:58 Burner Control 0 SW-version...:
Burner Control 1 SW-version...: Language......................: german
Basic Settings
--------------
Drain Valve time0......................................: 8.7 s
Drain Valve time1......................................: 26.1 s
Gas type................................... ............:
G20
Altitude pressure sensor............................: 255 (Electric: always -5000)
Altitude boiling point.......................... .......: 648
Diagnostic-Real Time Data-Sensors
act
max
lim
Time Stamp
dimension
Cabinet
B1.............................:
26.46
307.85
350
C
Quenching
B2...........................:
21.40
95.18
300
C
Temperature PCB........................: 35.34 81.11 80
20120514130736
C
Diagnostic-Real Time Data-Clima
Status Dry
Wet
Combi dimension
Clima Status 1-L.......................: 500 152.8 171.7 185.9 kPa
Clima Status 1-R.......................: 500 164.3 187.8 199.3 kPa
Clima Flap Y5..........................:
CLOSE
Clima Output P1........................: 0.00 V
Clima Humidity.........................:
4.00 %
Diagnostic-Water, CJ/Care Motor/Switch
Status Status Status dimension
Filling solenoid Y1....................: OFF
Volume Steam Generator (Norm Fill Calc):
5.48 5.22 4.38 l
CleanJet Pump M6........................: OFF
Door Contact S3........................: OFF
.......................................:
Diagnostic-Service History-SCC First time
Quantity
Last time
Service 10.............................:
20111210215318
5
20120418135651
Service 34.2...........................:
20111213084631
5
20120423131943
.......................................:
Diagnostic-Service History-Gas Top-Box First time
Quantity
Last time
14.....................................:
20120210145254
3
20120516135457
Diagnostic-Running Times-Components Value dim
Door Opening S3........................: 585
Ball Valve Openings S12................:
1381
Diagnostic-Running Times-Modes
Value dim
Hot Air Mode...........................:
192 h
medium.................................: 0 h
medium with steam generator descale (2): 0 0 h
medium w/o steam generator descale (2).: 0 0 h
Содержание CombiMaster Plus CM
Страница 1: ... V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08 ...
Страница 3: ... 3 V08 en SCC ...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS ...
Страница 25: ... 25 V08 en SCC ...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active ...
Страница 74: ...V08 en SCC 74 ...