- 61 -
V08 en, SCC
CCare: Error messages - Abort program SCC
Possible error messages during ClCare (ref: error trees in Trouble shooting manual)
The error is only shown at the end of the program.
Display
Problem
For repair refer to error tree.
Reset error memory:
from SW 7-00-08
after repair cancel error
by:
Reset error memory:
SW before 07-00-08
after repair cancel error by:
Service 10
SC pump and hose
Function test
Cleanjet
refer to fault tree
No water
Y1, water tap
open water tap, clean
strainer
Service 41
Y3, moistening nozzle blocked (CDS)
Function test
Cleanjet
Rinse with tabs
Service 42
Y4, Care valve blocked (CDS)
Rinse with tabs
Service 27
Drain valve not closing
refer to fault tree
Service 25
Cleanjet pump and hose
refer to fault tree
Service 44
Steam heating insufficient (B1), E/2
Rinse with tabs
Service 40
Care pump and hose
Rinse with tabs
Service 110 SC pump M4, level electrode
Abort
Service 120 Y1, level electrode
Abort
In case an error occurs, the unit will stop the cleanjet process and automatically start an internal abort cycle. At th
end of this abort cycle the error message is shown.
The same error message is shown when the user starts a cleanjet process again the next day.
To clear the error, the hardware problem must be solved and the error must be reset by the proper reset pro-
gram.
CleanJet interrupt
Should a running CleanJet program be interrupted by power failure or the unit has intentionally been switched
off, an ABORT program of approx. 27min starts automatically to bring the unit back into safe operation mode.
This ABORT program can not be shortened or aborted again but must be completed successfully.
The cabinet will be flushed with CleanJet pump M6. The steam generator will be filled with the Care valve Y4,
emptied with SC Pump M4 and then overfilled with the solenoid valve filling Y1. Now the steam generator will
be emptied once again and then refilled.
Finally there is a short steam phase (neutralisation of the steam generator).
Содержание CombiMaster Plus CM
Страница 1: ... V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08 ...
Страница 3: ... 3 V08 en SCC ...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS ...
Страница 25: ... 25 V08 en SCC ...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active ...
Страница 74: ...V08 en SCC 74 ...