- 23 -
V08 en, SCC
To use the following functions connect a USB Stick to the USB interface
PIn -
Load programs from USB Stick onto unit (Program In)
Pout - Load programs from unit onto USB Stick (Program out)
Programs can not be interchanged from SCC or SCC_WE to CM_P and vice versa.
Now set mode switch to Prog/Start and select desired additional program with temperature dial.
Import (Pin):
Should no „progs.xml“ file exist on the USB stick, Pin is blinking (Import not possible, Start key without function).
Should a „progs.xml“ file exist on the USB stick, Pin is showing steady. Import of programs is started by pressing
Start/Prog key. During the import time the Prog/Start-LED is blinking.
Export (Pout):
In case a „progs.xml“ file already exists on the USB stick, Pout is blinking;
Note: Pressing Start key now would overwrite the existing program file!
If Pout is showing steady the programs can be downloaded by pressing Start key. During the download process
the Prog/Start-LED is blinking.
Sout - Copy Service Data to stick
Hout - Copy HACCP Data to stick
As soon as the Start key is pressed, download starts and a LED is circling in the time display.
Program Lock
Select any program number, press timer key and set time to 110 min. Keep timer key pressed and press Prog/
Start key, “P” (Program Lock) is displayed.
When now selecting Prog/Start, “P---” is displayed for 2 seconds.
(Deactivation with same procedure.)
ESG - Empty Steam Generator manually (only with open door)
Close water tap
Press Start - SC pump runs for 45 seconds
°C°F - Setting °C >=< °F
Press Start - display changes from °C to °F or vice versa
rtc - (real time clock) Setting of date and time for HACCP protocol
Confirm the individual settings of hour, minute etc by pressing the START key.
Ethernet connection
Setting IP address: (only possible when Ethernet PCB is installed)
Select IP 1 for first block. Set block number with timer pot. Press Prog/Start to confirm. Select IP2 with tempera
-
ture dial etc.
Setting Gateway Address:
After entering IP 4 the display will switch over to GAt 1 automatically. Set block number with timer pot. Press
Prog/Start to confirm. Select GAt 2 with temperature dial etc.
Setting Subnet address:
After entering GAt 4 the display will switch over to Sub 1 automatically. Set block number with timer pot. Press
Prog/Start to confirm. Select Sub2 with temperature dial etc.
Additional function
Содержание CombiMaster Plus CM
Страница 1: ... V08 en SCC CMP 09 2018 Training Manual SelfCookingCenter SCC SCC_XS CombiMaster Plus CMP CM V08 ...
Страница 3: ... 3 V08 en SCC ...
Страница 10: ...V08 en SCC 10 Index E Index G Index H I Index I SCC XS ...
Страница 25: ... 25 V08 en SCC ...
Страница 64: ...V08 en SCC 64 SCC Service level pwd TECLEVEL Process is active ...
Страница 74: ...V08 en SCC 74 ...