V08 en, SCC
- 6 -
B1
B3.1 - 3.6
F4
P1
M4
M6
Y1
Y2
Y3
B2
M1
S2
M7
S12
B4
B5
F3
S3
Y4
S11
M12
Care
Y5
SCC
Block diagram SCC
B1
Thermocouple interior cabinet
B2
Thermocouple control box
B3.1-B3.6
Thermocouples core temperature
B3
Thermocouples core temperature (CM_P)
B4
Thermocouple humidity
B5
Thermocouple steam generator (preheat, 180°C (356°F) max)
F3
Safety thermostat steam generator 160°C (320°F)
F4
Safety thermostat interior cabinet 360°C (680°F)
M1
Fan motor (Floor unit: top)
M2
Fan motor (Floor unit: bottom)
M4
SC-pump
M6
CleanJet pump (SCC_WE)
M7
Motor drain valve / ball valve (SCC_WE)
M12 Care pump (SCC_WE)
S2
Level electrode
S3
Door reed switch
S11
CDS sensor (SCC_WE)
S12
Micro switch drain valve
P1
Differential Pressure sensor humidity
Y1
Solenoid valve filling
Y2
Solenoid valve control box
Y3
Solenoid valve moistening (SCC_WE)
Y4
Solenoid valve Care (SCC_WE)
Y5
Solenoid valve Clima