Remote Commands
R&S
®
ZNH
255
User Manual 1334.5985.02 ─ 02
If necessary, the corresponding delta marker is activated first.
This command is an event and therefore has no *RST value and no query.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
DELTamarker selects the deltamarker.
Example:
CALC:DELT3:MAX
Moves delta marker 3 to the maximum peak.
Usage:
Event
CALCulate<1...2>:DELTamarker<1...6>:MAXimum:NEXT
This command positions a delta marker on the next smaller trace maximum.
If necessary, the corresponding delta marker is activated first.
This command is an event and therefore has no *RST value and no query.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
DELTamarker selects the deltamarker.
Example:
CALC:DELT2:MAX:NEXT
Moves delta marker 2 to the next smaller maximum peak.
Usage:
Event
CALCulate<1...2>:DELTamarker<1...6>:MINimum[:PEAK]
This command positions a delta marker on the current trace minimum.
If necessary, the corresponding delta marker is activated first.
This command is an event and therefore has no *RST value and no query.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
DELTamarker selects the deltamarker.
Example:
CALC:DELT3:MIN
Moves delta marker 3 to the trace minimum.
Usage:
Event
CALCulate<1...2>:DELTamarker<1...6>:X
<FrequencyOrTime>
This command positions a delta marker on a particular coordinate on the horizontal
axis.
Note that it is possible to place the marker outside the visible trace. In that case, this
value is invalid.
If necessary, the corresponding delta marker is activated first.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
DELTamarker selects the deltamarker.
Remote Control - Commands