Hardware environmental monitoring alarm can be recorded in the current hardware
environment monitoring alarm table and hardware environment monitoring history alarm
table automatically without configuring manually.
Trap output
Alarms are output to the NMS in Trap mode.
Trap output has global switch and all monitored alarm events still have their own Trap alarm
output switches. When enabling the global switch and monitored alarm events switches
simultaneously, the alarm will generate Trap output.
Table 12-7 describes Trap information.
Table 12-7
Trap information
Field
Description
Alarm status
asserted (current alarm)
cleared (alarm recovery)
clearall (clear all alarm)
Alarm source
device (global alarm)
Interface number (interface status alarm)
Timestamp
Alarm time, in the form of absolute time
Alarm event type
dev-power-down (power-down alarm)
power-abnormal (power-abnormal alarm, one of two powers
is power down.)
high-temperature (high-temperature alarm)
low-temperature (low-temperature alarm)
all-alarm (clear all alarms)
Syslog output
Record alarms to Syslog.
Syslog output has global switch and all monitored alarm events still have their own Syslog
alarm output switches. When the global switch and monitored alarm events switches are
concurrently enabled, the alarm will generate Syslog output.
Table 12-8 describes Syslog information.
Table 12-8
Syslog information
Field
Description
Facility
The module name generating alarm, the hardware environment
monitoring module is fixed as alarm.
Severity
Level, the same as defined in system logs. For details, see Table 12-
4.
Mnemonics
Alarm event type. For details, see Table 12-7.
Msg-body
Main body, describing alarm event contents.