Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
12 System management
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
509
……
SwitchB#show lldp local config
System configuration:
------------------------------------------------------------------
LLDP enable status: enable (default is disabled)
LldpMsgTxInterval: 60 (default is 30s)
LldpMsgTxHoldMultiplier: 4 (default is 4)
LldpReinitDelay: 2 (default is 2s)
LldpTxDelay: 9 (default is 2s)
LldpNotificationInterval: 10 (default is 5s)
LldpNotificationEnable: enable (default is enabled)
------------------------------------------------------------------
Port Status Packet destination-mac
--------------------------------------------------------
GE1/1/1 enable 0180.C200.000E
GE1/1/2 enable 0180.C200.000E
GE1/1/3 enable 0180.C200.000E
GE1/1/4 enable 0180.C200.000E
GE1/1/5 enable 0180.C200.000E
GE1/1/6 enable 0180.C200.000E
……
Use the
show lldp remote
command to show neighbor information.
SwitchA#show lldp remote
Port ChassisId PortId SysName MgtAddress ExpiredTime
-------------------------------------------------------------------------
gigaethernet1/1/1 000E.5E02.B010 gigaethernet1/1/1 SwitchB
10.10.10.2 106
……
SwitchB#show lldp remote
Port ChassisId PortId SysName MgtAddress ExpiredTime
-------------------------------------------------------------------------
gigaethernet1/1/1 000E.5E12.F120 gigaethernet1/1/1 SwitchA
10.10.10.1 106
……
12.4 Optical module DDM
12.4.1 Introduction
Optical module Digital Diagnostics Monitoring (DDM) on the ISCOM2600G-HI series
switch supports Small Form-factor Pluggable (SFP) and 10GE SFP+ diagnosis.
The fault diagnostics function of SFP provides the system a performance monitor method.
The network administrator analysis the monitor data provided by SFP to predict the age of
transceiver, isolate system fault and authenticate modules compatibility during installation.