Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
4 Ring network protection
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
202
Step
Command
Description
6
Raisecom(config)#ethernet
line-protection trap enable
(Optional) enable ELPS Trap to be
reported to the NMS.
By default, ELPS Trap to be reported to
the NMS is disabled.
Use the
ethernet line-protection trap
disable
command to disable ELPS Trap.
4.2.5 Configuring ELPS fault detection mode
Configure the ELPS fault detection mode for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#ethernet line-
protection
line-id
{ working |
protection } failure-detect
physical-link
Configure the fault detection mode
of the working line/protection line to
physical link.
By default, it is physical link.
Raisecom(config)#ethernet line-
protection
line-id
{ working |
protection } failure-detect cc
[ md
md-name
] ma
ma-name
level
level
mep
local
-
mep-id
remote
-
mep-id
Configure the fault detection mode
of the working line/protection line to
CC.
This fault detection mode cannot
take effect unless you finish related
configurations on CFM.
Raisecom(config)#ethernet line-
protection
line-id
{ working |
protection } failure-detect
physical-link-or-cc [ md
md-
name
] ma
ma-name
level
level
mep
local
-
mep-id
remote
-
mep-id
Configure the fault detection mode
of the working line/protection line to
failure-detect physical-link-or-cc.
In this mode, a Trap is reported
when a fault is detected on the
physical link/CC.
This fault detection mode cannot
take effect unless you finish related
configurations on CFM.
Fault detection modes of the working line and protection line can be different.
However, we recommend keeping fault detection mode configurations of the working
line and protection line consistent.
4.2.6 (Optional) configuring ELPS control
Configure ELPS control for the ISCOM2600G-HI series switch as below.