Advanced parameters
Others
Query timeout [s]
Default = 3 [1 - 31]
When any Remote doesn't communicate with the Base within a Query timeout
period, Base station transmits 'query packet' in order to find out whether this
'non-communicating' Remote has anything to send even if other Remotes have
continuing data transfers.
NOTE: The Modulation rate and total number of Remotes should be considered
when setting this parameter. If the Modulation rate is low and the network
contains a large number of Remotes, the Query timeout must be long enough
to allow a query packet to be sent to every remote within the network and also
allow time for data transactions as well.
Broadcast repeats
Default = 3 [0=Off, 15=Max]
Every broadcast is repeated a given number of times. Broadcast repeats = 0
turns off broadcast repetition. Broadcast frames aren't acknowledged, hence
the need for repetition.