Tab. 10.5: Maximum voltage and current of individual interfaces
recommended
min. cross section
of Cu wire
max. current
max. voltage
IN/OUT
V03VH-H 2×0.5
5 A
30 VDC
DC Power
0.5 mm
2
V03VH-H 1×0.5
10 mA
30 VDC
SI
0.5 mm
2
V03VH-H 1×0.5
10 mA
30 VDC
Alarm input
0.5 mm
2
V03VH-H 1×0.5
2 A
30 VDC
Alarm output
0.5 mm
2
LiYCY 4×0.14
60 mA
±15 VDC
RS232
0.14 mm
2
LiYCY 4×0.14
60 mA
±15 VDC
RS485
0.14 mm
2
0.5 A
5 VDC
USB
0.5 mm
2
STP CAT 5E
±2.5 VDC
Ethernet RJ45
See Fig. 10.2, “ATEX Certificate RipEX, 1/3”
10.6. Conditions of Liability for Defects and Instructions for Safe Operation
of Equipment
Please read these safety instructions carefully before using the product:
•
Liability for defects does not apply to any product that has been used in a manner which conflicts
with the instructions contained in this operator manual, or if the case in which the radio modem is
located has been opened, or if the equipment has been tampered with.
•
The radio equipment can only be operated on frequencies stipulated by the body authorised by the
radio operation administration in the respective country and cannot exceed the maximum permitted
output power. RACOM is not responsible for products used in an unauthorised way.
•
Equipment mentioned in this operator manual may only be used in accordance with instructions
contained in this manual. Error-free and safe operation of this equipment is only guaranteed if this
equipment is transported, stored, operated and controlled in the proper manner. The same applies
to equipment maintenance.
•
In order to prevent damage to the radio modem and other terminal equipment the supply must always
be disconnected upon connecting or disconnecting the cable to the radio modem data interface. It
is necessary to ensure that connected equipment has been grounded to the same potential.
•
Only undermentioned manufacturer is entitled to repair any devices.
10.7. Important Notifications
Sole owner of all rights to this operating manual is the company RACOM s. r. o. (further in this manual
referred to under the abbreviated name RACOM). All rights reserved. Drawing written, printed or repro-
duced copies of this manual or records on various media or translation of any part of this manual to
foreign languages (without written consent of the rights owner) is prohibited.
RACOM reserves the right to make changes in the technical specification or in this product function or
to terminate production of this product or to terminate its service support without previous written noti-
fication of customers.
RipEX Radio modem & Router – © RACOM s.r.o.
216
Safety, environment, licensing
Содержание RipEX
Страница 2: ......
Страница 42: ... DQ Data Quality Min 180 PER Packet Error Rate Max 5 RipEX Radio modem Router RACOM s r o 42 Network planning ...
Страница 222: ...Fig 10 3 ATEX Certificate RipEX 2 3 RipEX Radio modem Router RACOM s r o 222 Safety environment licensing ...
Страница 223: ...Fig 10 4 ATEX Certificate RipEX 3 3 223 RACOM s r o RipEX Radio modem Router Safety environment licensing ...