300–400 MHz/70 cm band – 0.5 W RF power
15
30
2.9
4.6
single dipole
OV380.1
20
40
5.8
7.6
stacked double dipole
OV380.2
20
40
5.8
7.6
3 element directional Yagi
SA380.3
20
45
7.4
8.7
5 element directional Yagi
SA380.5
30
70
17.8
12.5
9 element directional Yagi
SA380.9
Tab. 10.4: Minimum Safety Distance 928–960 MHz
928–960 MHz – 8 W RF power
Dist. where the FCC limits are met for
Gain G
[–]
Gain G
[dBi]
Antenna description
Antenna
code
General Population
/ Controlled Expos-
ure [cm]
General Population
/ Uncontrolled Ex-
posure [cm]
30.8
69.0
2.92
4.65
single dipole
OV900.1
48.9
109.3
7.33
8.65
5 element directional Yagi
SA900.5
92.1
205.9
26.0
14.15
12 element directional Yagi
SA900.12
10.3. High temperature
If the RipEX is operated in an environment where the ambient temperature exceeds
55 °C, the RipEX must be installed within a restricted access location to prevent human
contact with the enclosure heatsink.
10.4. RoHS and WEEE compliance
This product is fully compliant with the European Parlament's 2011/65/EU RoHS (Restriction of Certain
Hazardous Substances in Electrical and Electronic Equipment) and 2012/19/EU WEEE (Waste Elec-
trical and Electronic Equipment) environmental directives.
Restriction of hazardous substances (RoHS)
The RoHS Directive prohibits the sale in the European Union of electronic equipment containing these
hazardous substances: lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls
(PBBs), and polybrominated diphenylethers (PBDEs).
End-of-life recycling programme (WEEE)
The WEEE Directive concerns the recovery, reuse, and recycling of electronic and
electrical equipment. Under the Directive, used equipment must be marked, collected
separately, and disposed of properly. RACOM has instigated a programme to manage
the reuse, recycling, and recovery of waste in an environmentally safe manner using
processes that comply with the WEEE Directive.
Battery Disposal
RipEX Radio modem & Router – © RACOM s.r.o.
214
Safety, environment, licensing
Содержание RipEX
Страница 2: ......
Страница 42: ... DQ Data Quality Min 180 PER Packet Error Rate Max 5 RipEX Radio modem Router RACOM s r o 42 Network planning ...
Страница 222: ...Fig 10 3 ATEX Certificate RipEX 2 3 RipEX Radio modem Router RACOM s r o 222 Safety environment licensing ...
Страница 223: ...Fig 10 4 ATEX Certificate RipEX 3 3 223 RACOM s r o RipEX Radio modem Router Safety environment licensing ...