Description
Parameter
Digital inputs levels:
0 to 5.6 VDC
logical level 0
7.2 to 40 VDC
logical level 1
Note
Negative input voltage is not recognised.
Digital outputs parametres:
1 A
Maximal continuous current
60 VDC, 42 VAC (Vrms)
Maximal switching voltage
60 W
Maximal switching capacity
•
Digital I/O Management
To manage digital inputs and outputs via TCP software is required that handles the TCP connection.
For test purposes e.g. telnet can be used. The payload contains the states of the four inputs/outputs:
The value 0 represents the state “off”, the value 1 the state “on”.
0
7
OUT2
OUT1
IN2
IN1
0
0
0
0
○
Monitor the digital inputs and outputs
Every change of digital inputs triggers a message of the above format to be sent. It also contains
the valid states of the outputs.
○
Set digital outputs
To set the states of the digital I/O send the following pattern as ASCII characters
Description
Pattern
Turn all digital outputs off
00000000
Turn output 2 on, turn output 1 off
00000001
Turn output 1 on, turn output 2 off
00000010
Turn output 1 on, turn output 2 on
00000011
○
Get status of digital inputs and output
To get the states of the digital I/O send the following pattern as ASCII characters
Description
Pattern
Request a message with all states
00010000
MG102, M!DGE, GPRS/EDGE/UMTS routers – © RACOM s.r.o.
32
Configuration
Содержание Midge MG102
Страница 2: ......
Страница 43: ...43 RACOM s r o MG102 M DGE GPRS EDGE UMTS routers Configuration...
Страница 80: ...3 1 9 System Authentication MG102 M DGE GPRS EDGE UMTS routers RACOM s r o 80 Configuration...
Страница 85: ...Troubleshooting Network Debugging 85 RACOM s r o MG102 M DGE GPRS EDGE UMTS routers Configuration...
Страница 113: ...113 RACOM s r o MG102 M DGE GPRS EDGE UMTS routers Troubleshooting...