TIMTER™ Multi-mode Digital Telemetry Transmitter
43
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
IC
Internal Clock
Rate
Report or set the internal clock
rate
This rate is used if the clock
source is set to internal (CS 1). It
should not be confused with “BR”,
which sets the rate of the internal
bit sync, which phase locks to the
externally applied data, if Clock-
free is enabled
If no argument is passed, the unit
reports the clock frequency. If a
valid frequency is given, the
internal clock frequency is set.
The frequency is in MHz.
Examples:
IC
Display current internal
clock rate
IC 4.95 Set internal clock rate to
4.95 MHz
Valid range is 0.002 MHz
– 46.0
MHz for most transmitters; some
legacy transmitters 0.002 MHz
–
28.0 MHz
Observes same bit rate limits as
HR/LR cmds (PCM/FM half)
Refer to section 4.2.1.1.9 for
additional IC command detail
Standard
Y
IC 5