TIMTER™ Multi-mode Digital Telemetry Transmitter
54
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
SV or SA
(or PS or
PW)
Save
Configuration
Saves the current transmitter
configuration to a user-selected
preset number, from 0 to 15
where 0 is the power-on default
unless hardware presets are
enabled
The SV command also allows the
user to assign an alias to the
desired preset.
Examples:
SV 1
Save current
configuration to preset 1
SV 7 xyz
Save current
configuration to preset 7 and
assign alias name “xyz”
*Refer to SV Note below for
exception
Standard
N/A
N/A
SW
Frequency
Sweep
Sweeps the transmitter frequency
between provided limits, with
provided step size, at a fixed rate
Examples:
SW
Displays current status
SW ? Displays command help
with status
SW 1 Start the sweep
SW 0 Stop the sweep
SW 1 2200.5 2394.5 1.0
Sweep channel 1
between 2200.5 MHz and 2394.5
MHz in 1.0 MHz steps
Refer to section 4.2.1.1.16 for
additional SW command detail
Standard
N/A
N/A