TIMTER™ Multi-mode Digital Telemetry Transmitter
18
Quasonix, Inc.
1.3.49 Wide Input Voltage Range Option
– WV
The standard TIMTER™ operates from +28 + 4 VDC. The WV option extends operating input voltage range as
shown in following table.
Voltage Ranges with WV Option
+8.0 to +34 VDC for 10 mWatt version
+8.0 to +34 VDC for 20 mWatt version
+8.0 to +34 VDC for 1 Watt version
+8.0 to +34 VDC for 2 Watt version
+12 to +34 VDC for 5 Watt version
+21 to +34 VDC for 10 Watt version
+21 to +34 VDC for 20 Watt version
+21 to +34 VDC for 25 Watt version
Note:
The WV option is not supported on 25 W S-band and 20 W L/C or S/C-band transmitters.
1.3.50 External Device Control
– XD
This option lets the user control the state and operation of the new TTL output pins on the switchbox interface
connector. Refer to section 4.2.1 for command descriptions.