TIMTER™ Multi-mode Digital Telemetry Transmitter
44
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
ID
Internal Data
Gen
Report or set the internal data
pattern
This setting is used if the Data
Source is set to internal (DS 1)
and the Clock Source is set to
internal (CS 1).
When setting the data, the
argument must be “PN6” (or
“PN06”), “PN11”, “PN15”, or
“PN23”, or a valid 4 digit
hexadecimal value, or USER. If
USER, two or more arguments
may be included in format:
ID USER pattern bitlen
Pattern = A 32 bit hex pattern
Bitlen = Number of bits (1-32) in
the user pattern
Examples:
ID
Report the internal data
pattern
ID PN15
Set internal data
pattern to PN15
ID USER AA55 Set internal data
pattern to 0xAA55
In SOQPSK mode, ID USER
5555 or ID USER AAAA will
result in an unmodulated carrier,
at the nominal carrier frequency.
Standard
Y
ID PN15
IMN
Internal Model
Number
Display the internal model
number for the transmitter
Standard
N/A
N/A