TIMTER™ Multi-mode Digital Telemetry Transmitter
77
Quasonix, Inc.
6 Performance Specifications
6.1 RF Output
The minimum RF output power is one of the following: 10 mW, 20 mW, 5 W, 10 W, 20 W, or 25 W with the RF
load VSWR < 2:1 at all phase angles from 0 to 360 degrees.
6.2 Electrical Current
The electrical current drain for TIMTER™ transmitters is provided in Table 14.
Table 14: DC Input Current at Standard Input Voltage
Band Type
Wattage
Maximum
Current
Typical Current @ 28
VDC
L or S band
10 mWatt
0.3 amps
0.25 amps
L or S band
20 mWatt
0.35 amps
0.30 amps
L or S band
5 Watt
1.0 amps
0.85 amps
L or S band
10 Watt (2in
3
packages)
1.4 amps
1.1 amps
L or S band
10 Watt (>2in
3
packages)
1.8 amps
1.5 amps
L/S band
5 Watt
1.2 amps
1.0 amps
L/S band
10 Watt
2.2 amps
1.8 amps
L/S band
18 or 20 Watt
3.2 amps
2.8 amps
L band
18 or 20 Watt
3.2 amps
2.8 amps
S band
18 or 20 Watt
2.8 amps
2.5 amps
S band
25 Watt
3.2 amps
2.9 amps
C band
10 mWatt
0.3 amps
0.25 amps
C band
5 Watt
1.5 amps
1.3 amps
C band
10 Watt
2.4 amps
1.9 amps
C-band
18 or 20 Watt
3.4 amps
3.0 amps
L/C band and S/C band
10 mWatt
0.3 amps
0.25 amps
L/C band and S/C band
20 mWatt
0.35 amps
0.30 amps
L/C band and S/C band
10 Watt
2.2 amps
2.0 amps
L/C band and S/C band
18 Watt
3.5 amps
3.2 amps
L/S/C band
10 mWatt
0.45 amps
0.40 amps