TIMTER™ Multi-mode Digital Telemetry Transmitter
53
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
SC
Set
Configuration
Priority
Set or show current configuration
priority setting.
Valid settings are:
1
– Ignore stored setting; read
frequency plug on power up
2
– Ignore frequency plug
(always)
Refer to section 4.2.1.1.15 for
additional SC command detail
PM or PF
Y
SC 1 or 2
(refer to
additional
detail)
SD
Digital Pot
Report the value of the digital pot
for HVA on the transmitter.
Range is 0 to 255
Standard
N/A
255
SI
Spectral
Inversion
Sets the modulation scaling to -1
* whatever the current scaling is
in order to invert the spectrum
This is in ADDITION to any
changes in modulation scaling
factor. That is, if you enter a
negative MS and then turn SI on,
you will have a NON_inverted
spectrum.
Examples:
SI
Report spectral inversion
status
SI 0
No inversion
SI 1
Invert the spectrum
Standard
Y
SI 0
SN
Serial Number
Report the serial number for the
unit
Standard
N/A
N/A
SS
Show Settings
Displays most of the common
device settings in one compact
display
Standard
N/A
N/A