TIMTER™ Multi-mode Digital Telemetry Transmitter
70
Quasonix, Inc.
For example:
SY 5000 (sets status period to 5 seconds)
SY 5000 100 (sets status header output once every 100 status updates
The SY command is defined as follows.
Mode
– Current mode number (such as 0 = PCM/FM)
CF Rate
– Clock free estimated data rate. This rate is based on the external data input (TTL or RS-422) even if
internal data is presently in use (CS = 1).
Freq
– Tuned frequency
Tmp
– Current temperature
Crate
– Clock filter clock rate. This is the actual over the air bit rate, regardless of the selected data source, and
including any increases due to encoding (LDPC or convolutional). IN clock free automatic mode, it may differ from
CF Rate because it will track the bit sync rate (exact, if locked) rather than the clock free estimated rate
(approximate).
This example display shows selected parameters for one channel.
CRateB0
CFRate1
Mode 1
Freq 1
Temp 1
(b/s)
(b/s)
(Hz)
(C)
7812666
0
0
1852000000
32.5