Technical Guide: RDMS Telnet and Serial Control
46
Quasonix, Inc.
Lock detect output = Lock detect active High (+) normal operation
One of the sources is HyperTrack data. When HyperTrack is enabled, the lock detect output becomes HyperTrack
data, and is then unavailable.
The full command syntax follows:
DSO [<c> [<s>|<p>|M <m>]]
<c> <s> - Sets channel <c> source to <s>
where:
<c> - Channel
L - Lock detect output
<s> - Signal source
F0
–
Fixed value 0
F1
–
Fixed value 1
LD
–
Lock detect
SD
–
Sync detect
PL
–
PCM frame lock
PS
–
PCM sub-frame valid
HT
–
HyperTrack data
BE
–
BERT error
<c> <p> - Sets channel <c> polarity to <p>
where: <p> - Output polarity
{0|+} - Active high (normal)
{1|-} - Active low (inverted)
M <m> - Sets channel <c> output mode to <m>
where: <m> - Output mode
0 - Allows normal output
1 - Forces output to 1 (active)
-1 - Forces output to 0 (inactive)
Example: