Technical Guide: RDMS Telnet and Serial Control
16
Quasonix, Inc.
T <t> - Sets antenna mode scan type to <t>
where: <t> - Scan type
C - Conical scan
E - E-scan
R <r> - Sets antenna mode scan rate to <r>, 10.00 to 50.00 Hz
ACU [AM [<p>|S <s>|B <b>]] - Antenna control unit AM settings
<p> - Sets AM output polarity to <p>
where: <p> - Polarity
{0|+} - Normal
{1|-} - Inverted
S <s> - Sets AM output scale to <s>, -128.0 to 128.0
B <b> - Sets manual mode AM detector bandwidth to <b>, 5.00 to 50000.00 Hz
ACU [AGC [<p>|S <s>|T <n>]] - Antenna control unit AGC settings
<p> - Sets AGC output polarity to <p>
where: <p> - Polarity
{0|+} - Normal
{1|-} - Inverted
S <s> - Sets AGC output scale to <s>, 1.0 to 50.0 dB/V
T <n> - Sets manual mode AGC time constant to <n>, 0.1 to 1000.0 ms
Examples:
ACU
Report ACU related status
PCMFM$acu
ACU mode manual
AGC compensated AM on
Antenna scan type conical
Antenna scan rate 30.0 Hz
Manual AM bandwidth 100.0 Hz
Manual AGC time constant 100.0 ms
AM output po
AGC output po
AGC output scale 10.0 dB/V
AM scale 1.0