Technical Guide: RDMS Telnet and Serial Control
11
Quasonix, Inc.
Mnemonic
Name
Description
Option (s)
Required
Mode
Restriction
CMB
Combiner
Control
Displays and controls
combiner settings
Standard
None
CP
Clock Polarity
Report or set clock polarity
inversion state
Standard
For Asynch
PSK (legacy)
modes, CP A
and CP B must
be specified
separately
DA
Downconverting
Antenna
Displays and controls
receiver C band to P band
downconverting antenna
P band
enabled
receiver
None
DD
Differential
Decoding
Enable or disable differential
decoding
Standard
SOQPSK
DHI
High Speed
Digital Input
Displays and controls high
speed digital input settings
Standard
None
DHO
High Speed
Digital Output
Displays and controls high
speed digital output settings
Standard
None
DLI
Low Speed
Digital Input
Displays and controls low
speed digital input settings
Standard
None
DLO
Low Speed
Digital Output
Displays and controls low
speed digital output settings
Standard
None
DOM
Digital Output
Muting
Control shut down of clock
and data outputs
Standard
None
DP
Data Polarity
Report or set data polarity
inversion state
Standard
For Asynch
PSK (legacy)
modes, DP A
and DP B must
be specified
separately
DQ
Data Quality
Encapsulation
and Metrics
Display and control data
quality encapsulation and
DQ metrics
Standard
ARTM modes
DR
Derandomizer
State
Report or set the
derandomizer state
Standard
None
DSO
Digital Status
Output
Controls the source, polarity,
and override states
Standard
None
FEC
Forward Error
Correction Mode
Report FEC status for
enabled modes
-K7
Legacy PSK
FL
Force Lock
Indication
Diagnostic tool to force the
system to indicate locked or
unlocked
Standard
None