Technical Guide: RDMS Telnet and Serial Control
66
Quasonix, Inc.
SDI 1 Enable SDI
SDI E
- Sets signal degradation information external threshold
Examples:
SDI E A
Set SDI external threshold to automatic
SDI I 1943
Set SDI external threshold to 1943
Valid range 0 to 65535
SDI I
- Sets signal degradation information internal threshold
Examples:
SDI I A
Set SDI internal threshold to automatic
SDI I 4242
Set SDI internal threshold to 4242
Valid range 0 to 65535
SDI L
- Sets signal degradation information lock state
Examples:
SDI L 0
Set SDI lock state to normal operation
SDI L 1
Set SDI lock state to forced active
SDI L -1
Set SDI lock state to forced inactive
SDI P
- Sets signal degradation information source polarity
Examples:
SDI P 0
Set SDI source polarity to active high (normal)
Valid active high 0 or +
SDI P 1
Set SDI source polarity to active low (inverted)
Valid active low 1 or -
SDI S
- Sets signal degradation information source
Examples:
SDI S P0
Set SDI data source to Physical Input 0
SDI S P1
Set SDI data source to Physical Input 1
SDI S CMB
Set SDI data source to Combiner
SDI T
- Sets signal degradation information tracking display enable or disable parameters
Examples:
SDI T 0
Disable SDI tracking display