Technical Guide: RDMS Telnet and Serial Control
18
Quasonix, Inc.
Options:
-h - Do not display header
AEQ [M {CMA|DD} <k>]
M CMA <k> - Sets EQ CMA Mu to <k>, 0.000 to 0.003906
M DD <k> - Sets EQ CMA Mu to <k>, 0.000 to 0.003906
AEQ [K {FF|FB} <k>]
K FF <k> - Sets EQ feed forward proportional constant to <k>, 0.000 to 0.999985
K FB <k> - Sets EQ feedback proportional constant to <k>, 0.000 to 0.999985
AEQ [MT {CMA|DD} <t>]
MT CMA <k> - Sets CMA MSE threshold to <k>, 0.000 to 0.999985
MT DD <k> - Sets DD MSE threshold to <k>, 0.000 to 0.999985
AEQ [CT <t>]
- Sets confidence threshold to <t>, 0.000 to 3.999939
AEQ [AR <e>|C <e>|R <r>|DD <e>]
AR <e> - Sets auto reset enable to <e>
C <e> - Sets power centering enable to <e>
R <e> - Sets reset <r>
where: <r> - Reset
0 - Run
1 - Reset
DD <e> - Sets decision directed enable to <e>
where: <e> - Enable
0 - Disabled
1
–
Enabled
AEQ TAPS [DFT][ <f>][ <o>]]
- Display equalizer source <s> in format <f> with options <o>
where: <f> - Format
N - Display using normal format - default
C - Display using CSV format
where: <o> - Options
IQ - Display complex values using CSV format - default
POL - Display polar values using CSV format