![Quasonix RDMS Скачать руководство пользователя страница 20](http://html2.mh-extra.com/html/quasonix/rdms/rdms_technical-manual_3540276020.webp)
Technical Guide: RDMS Telnet and Serial Control
19
Quasonix, Inc.
G - Display as graphic only
Examples:
AEQ
Report equalizer status
PCMFM$aeq
Adaptive equalizer enabled
EQ auto hold disabled
Decision directed error is NOT in use
Decision directed enabled
Reg enabled
Mean squared error (CMA) 0.014893
Mean squared error (DD) 0.855225
Average confidence 0.040588
Equalizer filters not reset
Equalizer IS in auto reset
Auto reset enabled
AEQ 0 Disable adaptive equalizer
AEQ 1 Enable adaptive equalizer
AEQ H x
Set equalizer hold below Eb/N0 to a value between -20.000 and 30.000 dB;
-100.000 sets equalizer hold to Off
AEQ T 0
Disable equalizer information tracking display
AEQ T 1
Enable equalizer information tracking display
2.1.1.4
Automatic Frequency Control - AFC
The Automatic Frequency Control command reports or sets various AFC parameters.
AFC [M <m>|H <t>|C {A|<c>}|L <m>|T {L|H} <t>|R <e> or AFC SYS <d>
M <m> - Sets AFC mode to <m>
where: <m> - mode
O - Off
H - Hold
T - Track
A - Acquire
H <t> - Sets AFC hold below Eb/N0 <t>, -20.000 to 30.000 dB or -100.000 is off
C A - Sets AFC coefficient to be automatically set based on bit rate
C <c> - Sets AFC coefficient to <c>, 0.0003511 to 46.018 seconds